Read More

Seen this product cheaper elsewhere?
Call 0345 2300 599Usage
ACOM 06AT is an automatic antenna tuner for HF + 6 m with integrated four-way antenna switch. The tuner automatically selects one of four available antenna outputs (as assigned in bands by the operator) and matches the impedance of the chosen antenna output by transforming it to 50 Ohm with SWR below 1.5:1 at the tuner input (typically below 1.3), providing an optimum load impedance for the amplifier.
Compatibility
The ACOM 06AT tuner is specifically designed and developed to work exclusively with the ACOM series of solid state (transistor) amplifiers, e.g., ACOM 600S, 700S, 1200S or ACOM 2020S.
Easy set-up of user tuning presets
For a CAT transceiver a single press of the TUNE button on the amplifier front panel is all you need.
Transparent (invisible) operation
After setting up the user presets (auto tune) for the frequency segments and antennas, the operator will not be involved with tuner operation.
Three kinds of frequency segments, according to antenna natural bandwidth
The operator can choose according to the nature of each of the four antennas: Narrow band - Sharp, Normal - Regular, and Broadband - Wide.
Capability of operation at fixed frequencies
This capability is available also.
Non-volatile memory
Non-volatile memory for user presets (auto tune), independent for the four antennas, the three types of segment width, and more than 1000 random fixed frequencies for each antenna.
User presets
The user presets are automatically loaded, following frequency and antenna selection changes.
Export (backup) of preset memory
Backup of preset memory to a computer file, import of previously made backup files from a computer to the tuner memory.
Helpful information
Information about the setting age, and alerts for settings that reach a certain age, defined by the operator in 4 possible age levels.
Power supply and control to the tuner
Power supply and control to the tuner, as well as status return from the tuner are facilitated over the coaxial cable between the amplifier and tuner, no need for additional cables or special control signals from the transceiver (the availability of CAT control from the transceiver will give further advantages to the setup).
Improved electromagnetic compatibility
Full tuning can be completed within 5 seconds (typically 2-3 seconds), at 25 W at the tuner input and less than 6 W at the antenna output; quick tuning (from nonvolatile-memory presets) is completed in less than 0.05 seconds with zero emitted signals.
Input SWR during full tuning cycles
Input SWR during full tuning cycles - below 2:1, preventing activation of transceiver PA protection.
Input SWR after completing a tuning cycle
Input SWR after completing a tuning cycle - below 1.5:1 (typically below 1.3:1).
Relays with gold-plated contacts
Relays with gold-plated contacts for excellent receive characteristics.
Relay switching
Relay switching will only take place when no RF current is flowing, preventing contact arcing critical for preventing contact oxidation, surface melting and material transfer (otherwise resulting in poor receiving performance) and to avoid any unwanted widening of the spectrum of signals, emitted during the tuning cycle.
Air-core coils and high-quality ceramic capacitors
Air-core coils (no magnetic materials) and high-quality NP0 (C0G) ceramic capacitors usage throughout the matching circuit.
Harmonic suppression
Improves harmonic suppression - the matching network is a low-pass L filter.
Saves space on the operating position
ACOM 06AT can be located up to 100 m (330 ft) away from the shack (in another room, but not outdoor).
Integrated antenna switch
Integrated four-way antenna switch - less coaxial cable, shorter unmatched sections, less losses.
Automatic and manual antenna switching
Antennas can be automatically and manually switched from the amplifier front panel. The last used antenna selection is memorized.
Customized antennas names and types
Indication and editing of names and types of antennas in editable freeform.
Protection mechanisms
Various protection mechanisms, including: antenna overvoltage, antenna overcurrent, excessive power during operation and tuning, extreme temperatures and power supply voltages, as well as relay hot-switching.
Safe power supply
Safe power supply voltage (26 VDC).
BYPASS mode
In BYPASS mode all components of the matching network are excluded, allowing direct operation of broadband antennas.
SERVICE menu
This menu allowing analysis of the tuner status and review of the used resource of coils and capacitors for all memorized and current tuning presets.
Lightning arrestor and bleeder resistor
Integrated lightning arrestor and bleeder resistor for protection against static discharges; automatic grounding of antennas on powering down.
Operating Frequency Range
- Continuous from 1.8 to 30 and from 50 to 54 MHz;
- Extensions and/or changes on request;
Minimum Range of the Matched Impedances (at Each of the Four Antenna Outputs)
- All impedances with SWR from 1:1 to 3:1 towards 50 Ohm, any phase angle, unbalanced input and output;
- For some frequencies and impedances, matching is possible at SWR above 3:1 at the antenna output (up to 10:1), but the maximum allowed power is reduced;
Maximum Allowed Input Power (PEP, Mean or Continuous Carrier, Without Mode Limitation)
- At antenna SWR below 2.5: 1500 W;
- At antenna SWR between 2.5 and 3: 1200 W;
- At antenna SWR between 3 and 5 (provided matching is possible): 500 W;
- At antenna SWR between 5 and 10 (provided matching is possible): 200 W;
- Operation with SWR above 10:1 is not allowed;
RF Input Characteristics
- Rated impedance: 50 Ohm unbalanced;
- Input connector type: UHF/PTFE (SO-239A) - 1 pc.;
- SWR during full tuning (basic cycle): No higher than 2:1;
- SWR immediately after full tuning: No higher than 1.5:1 (1.3:1 typically);
Antenna Outputs Characteristics, Antenna 1 to Antenna 4
- Rated impedance: 50 Ohm unbalanced;
- Maximum antenna output SWR: 3:1 (up to 10:1 with RF power limitations);
- Output connectors type: UHF/PTFE (SO-239A) - 4 pcs;
Full Tuning Duration (Basic Cycle)
Basic cycle for preparation of user full tuning settings, with automatic storage in the non-volatile memory:
- In the range of 1.8 to 10 MHz: No more than 5 seconds (2-3 seconds typically);
- In the range of 10 to 54 MHz: No more than 3 seconds (1-2 seconds typically);
Input Signal Needed to Prepare User Tuning Settings
- Non-modulated carrier power 25 W +3/-3 dB (12.5 to 50 W);
Power Supply
- +26 VDC, +10/-15%, consumption of 25 W at most;
- Supplied by an amplifier of the ACOM transistor series over the input RF coaxial cable;
Remote Control
- The remote control and indication from an amplifier of the ACOM transistor series is provided over the input RF coaxial cable of the tuner using a 60 kHz / 4800 bps bidirectional FSK modem;
Maximum Length of the Input Coaxial Cable
- The maximum length of the RF coaxial cable between the amplifier output and the tuner input is 100 m (330 ft) for a cable of RG213 type or similar. The cable characteristic impedance should be 50 Ohm and the DC resistance should be below 1 Ohm for inner and outer conductors altogether;
Size & Weight (operating, excluding fastening elements and connected cables)
- WxDxH: 212x312x158 mm, x.x kg (8.4x12.3x6.3 inches, x.x lbs.);
Shipping Size & Weight
- WxDxH: Approx. 382x459x348 mm, x.x kg (15.1x18.1x9.8 inches, xx.x lbs.);
- Please, contact us for shipment details;
Operating Environment
- Temperature range: -10 to +40 degrees Celsius (14 degrees F to 104 degrees F);
- Relative air humidity: Up to 95% @ +35 degrees Celsius (95 degrees F);
- Height above sea level: up to 3050 m (10000 ft) without output deterioration.
Shipping & Delivery
We offer UK and international delivery services, including next working day and selected weekend options for eligible orders. Available services, prices and estimated delivery times are displayed at checkout.
Delivery Information
Delivery options depend on the parcel's size, weight, contents and destination. Express and weekend services are subject to availability and cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.
Returns & Cancellations
To arrange a return, please contact ML&S or complete our returns form. You may also exercise your statutory right to cancel by email or another clear statement, without completing the form.
Changed Your Mind?
Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.
You must notify us of your cancellation within this period and return the goods within a further 14 days.
Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging, and all supplied accessories.
You may inspect goods as you would in a shop. Handling beyond what is necessary to inspect them may result in a lawful deduction for diminished value.
Exceptions
Modified Equipment & Reversal Charges
Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.
ML&S may charge a reasonable fee to reverse physical modifications and restore the equipment to its original factory specification. Any such charge will be agreed in advance and deducted from your refund.
Custom-Made Cable Assemblies
Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.
Software & Labour Charges
Labour and modification charges requested by the customer are non-refundable once the work has been completed.
Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.
Return Postage Charges
Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods, where permitted by law. You may arrange your own suitable return postage or use one of our optional prepaid services.
Standard Parcels
Royal Mail Return Label
£5.95
Per parcel
For eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection included.
Larger Parcels
DPD Return Label
£7.95
Per parcel
For larger or heavier parcels and any shipments with batteries.
Collection Service
DPD Collection
£25.00
Per parcel
Available upon request for eligible addresses, subject to availability.
Prepaid return charges will be confirmed before booking and deducted from your refund.
These prices apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.
Faulty or Incorrectly Supplied Goods
Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. ML&S will arrange a free return in these circumstances.
Refunds
Refunds are processed without undue delay following receipt and inspection of returned goods, and no later than 14 days after we receive goods returned under statutory cancellation rights.
Refunds will be issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised.
Warranty Terms & Conditions
New Equipment Warranty
Minimum 2-Year Warranty
All new products supplied by ML&S carry a minimum two-year warranty against manufacturing defects, excluding batteries, which are covered by separate warranty terms.
Some manufacturers provide extended warranties, such as the three-year warranty available on eligible Yaesu equipment. Any additional coverage is subject to the manufacturer's terms and conditions.
Our workshop may assess and repair faulty equipment on site or refer it to the manufacturer or an authorised service centre where necessary.
Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.
All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.
International Returns & Warranty
Unless otherwise stated, ML&S warranty servicing is carried out in the UK. International customers must contact us before returning goods to confirm shipping and customs requirements.
International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.
ML&S accepts no responsibility for additional charges resulting from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before return of the goods.
Need Help With a Return?
Our team can assist with returns, postage arrangements, modifications and warranty claims.
Nothing in these terms excludes or limits your statutory consumer rights.