OM Power OM-2000A+ 2kW Automatic HF & 6m Linear Amplifier
SKU Part Number: OM-2000A-PLUS
Custom OM Power Control Cable Would You Like a Custom Control Cable...
Read More
Special Price £5,194.00 Regular Price £5,294.00
Pre Order
call

Seen this product cheaper elsewhere?

Call 0345 2300 599
Custom OM Power Control Cable

Would You Like a Custom Control Cable Made?

Select your radio manufacturer and model below, then click the button to send our team the details of your station.

Can't find your radio? Contact us at [email protected] and let us know which transceiver you would like to use.
Selecting a radio does not guarantee that a custom cable can be produced. Our team will confirm the required connections and compatibility before taking an order.
2kW+ Fully Automatic HF & 6m Amplifier

OM Power OM2000A+

A fully automatic HF and 50MHz ceramic-tetrode linear amplifier delivering more than 2kW on HF and up to 1.5kW on 6m, with CAT integration, RF frequency sensing, automatic PA tuning, LAN remote control and full QSK.

HF SSB / CW
2,000W+
Automatic high-power HF operation.
50MHz SSB / CW
1,500W
High-power 6m operation from the same amplifier.
RTTY
1,500W
Manufacturer-rated high-duty-cycle output.
POWER STAGE
1 × FU-728F
High-power ceramic tetrode.
Automatic HF + 6m Power

Change Frequency. The Amplifier Follows.

The OM Power OM2000A+ covers amateur bands from 1.8 to 29.7MHz, including WARC allocations, together with 50MHz.

CAT communication or RF frequency sensing allows the amplifier to follow the operating frequency, select the correct band and recall the appropriate tuning condition automatically.

FU-728F Ceramic Tetrode

More Than 2kW on HF

The OM2000A+ uses a single FU-728F ceramic tetrode, producing more than 2kW in SSB and CW on the HF amateur bands.

The amplifier is also rated for 1.5kW SSB/CW on 50MHz and 1.5kW RTTY.

Automatic PA Tuning

Stored Tuning by Frequency Segment

Instead of manually adjusting TUNE and LOAD controls whenever frequency changes, the OM2000A+ stores and recalls amplifier tuning conditions according to the selected band and frequency segment.

OM Power specifies a response time of less than 0.5 seconds within the same band and less than 3 seconds when changing bands.

Automatic Tune Explained

Automatic Amplifier Tuning, Not an Antenna Tuner

The OM2000A+'s automatic tuning system adjusts the amplifier's own tuned output network. It does not replace an external antenna matching unit, so the antenna, feeder and switching system must still present an appropriate high-power load.

Fully Automatic Control

CAT or RF Frequency Sensing

OM Power specifies CAT support for Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio and Apache Labs ANAN, together with Icom CI-V information supplied through compatible microHAM devices.

If CAT information is unavailable, the OM2000A+ can automatically determine the operating frequency from the transmitted RF signal and select the appropriate band.

AUTO BAND
Automatic Band Switching
The correct amplifier band is selected automatically from CAT or detected RF frequency information.
AUTO TUNE
Frequency-Segment Memory
Stored tuning positions are recalled automatically as the operating frequency changes.
BAND DATA
External Filter Control
BCD band-data output can control compatible external band-pass filtering such as the OM6BPF.
ANTENNA CONTROL
Up to 10 Positions
BCD antenna-control output can address up to ten external antenna-switch positions.
High Power Gain

Full Output from Around 40-60W Drive

The OM2000A+ provides approximately 17dB power gain, with around 40 to 60W of transceiver drive required for full output depending on band, tuning and load conditions.

RF Performance

Clean Output from HF through 6m

OM Power specifies intermodulation distortion at better than -32dBc.

Harmonic suppression is specified at a minimum of -50dBc, improving to better than -70dBc on 50MHz.

Load Protection

Automatic Reflected-Power Protection

Maximum specified output SWR is 3:1. If reflected power reaches approximately 350W or higher, the amplifier automatically switches to STBY.

Input impedance is 50 ohms, with input VSWR specified below 1.5:1.

Comprehensive Protection

Monitoring the Complete Power Amplifier

The OM2000A+ monitors SWR, anode current and voltage, screen current and voltage, grid current and voltage, heater voltage, PA tuning and operating temperature.

Soft-start circuitry limits mains inrush and a cabinet safety interlock prevents normal switch-on while the amplifier is open. Faults and warnings are retained in memory to aid maintenance and diagnosis.

VSWR too high
Anode current too high
Anode voltage error
Screen current too high
Screen voltage error
Grid current too high
Grid voltage error
Heater voltage error
PA mistuning
Temperature too high
Soft-start protection
Open-cover switch-on interlock
QSK
Vacuum RF Relay
Built-in vacuum RF antenna relay provides QSK transmit and receive switching.
COOLING
Programmable Cooling
Centrifugal and axial blowers with three programmable operating modes.
DISPLAY
4.3in Colour Touchscreen
Operating information, tuning status, alarms and amplifier parameters are available from the front panel.
Easier Tube Replacement

Automatic Bias Setup

Following tube replacement, the OM2000A+ can automatically establish the required anode-current bias, avoiding a separate manual bias-adjustment procedure.

Service & Transport

Detachable High-Voltage Transformer

The high-voltage transformer can be detached, reducing the weight of the individual sections when the amplifier needs to be transported or serviced.

Built-In LAN Control

Remote Monitoring and Control

The OM2000A+ incorporates a Lantronix XPORT network interface for remote control and monitoring using OM Power's Windows software.

The factory IP address is 192.168.1.211, with subnet mask 255.255.255.0 and gateway 192.168.1.1. OM Power recommends securing the XPORT web interface after installation.

High-Power Mains Supply

3kVA Toroidal Transformer

The amplifier uses a 3kVA toroidal transformer with switchable 220, 230 and 240V primary settings for 50/60Hz operation.

Other primary-voltage arrangements may be available for certain markets. Installation must provide an electrical supply suitable for the amplifier and comply with OM Power's instructions and applicable electrical regulations.

WIDTH
390mm
Compact footprint for an automatic 2kW-class valve amplifier.
HEIGHT
195mm
Allow sufficient clearance for cooling airflow.
DEPTH
370mm
Allow additional rear clearance for cables and ventilation.
WEIGHT
Approx. 24kg
Detachable transformer assists with transport and servicing.
Operating Power

Use Within Your Licence Conditions

The OM2000A+'s maximum RF capability may exceed the transmit power permitted by an operator's amateur-radio licence. Output power must always be set and operated within applicable licence conditions and local regulations.

Manuals, Firmware & Remote Software

OM2000A+ Downloads

OM Power provides the OM2000A+ user manual, automatic-tuning guide, remote-control software, firmware loader, firmware-upgrade instructions and current firmware releases through its official download centre.

View OM Power Downloads
Technical Specification

OM Power OM2000A+

Fully automatic HF and 50MHz ceramic-tetrode linear amplifier with automatic PA tuning, CAT and RF frequency detection, LAN remote control and full QSK.

Amplifier Type Fully automatic ceramic-tetrode HF and 50MHz linear amplifier
Frequency Coverage Amateur bands 1.8-29.7MHz including WARC bands, plus 50MHz
HF SSB / CW Output 2,000W+
50MHz SSB / CW Output 1,500W
RTTY Output 1,500W
Drive Power 40-60W for full output
Power Gain 17dB
Input Impedance 50 ohms
Input VSWR Less than 1.5:1
Output Impedance 50 ohms unbalanced
Maximum Output SWR 3:1
SWR Protection Automatic STBY at approximately 350W reflected power or higher
Intermodulation Distortion Better than -32dBc
Harmonic Suppression Minimum -50dBc
Harmonic Suppression, 50MHz Better than -70dBc

RF Power Stage & Automatic Tuning

Tube 1 × FU-728F ceramic tetrode
Automatic Tuning Automatic band and frequency-segment PA tuning
Same-Band Response Less than 0.5 seconds
Band-Change Response Less than 3 seconds
Automatic Bias Setup Supported following tube replacement
QSK Built-in vacuum RF antenna relay
Automatic Radio Control CAT plus RF frequency sensing
Supported CAT Manufacturers Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio and Apache Labs ANAN
microHAM Compatibility Icom CI-V output from compatible microHAM devices
RF Frequency Detection Automatic frequency reading where CAT is unavailable
Band-Pass Filter Control Yaesu-compatible BCD band-data output
External Antenna Control BCD output capable of addressing up to 10 antenna positions

Protection & Monitoring

VSWR too high
Anode current too high
Anode voltage error
Screen current too high
Screen voltage error
Grid current too high
Grid voltage error
Heater voltage error
PA mistuning
Temperature too high
Soft-start protection
Open-cover switch-on interlock
Mains Supply Switchable 220 / 230 / 240V AC, 50/60Hz; other primary arrangements available for certain markets
Transformer 1 × 3kVA toroidal transformer
Cooling Centrifugal blower plus axial blower, with three programmable operating modes
Display 4.3in colour touchscreen
LAN Interface Lantronix XPORT XP1001000-05R
Factory IP Address 192.168.1.211
Factory Subnet Mask 255.255.255.0
Factory Gateway 192.168.1.1
Remote Software LAN Ports 9999 and 10001
Dimensions 390 × 195 × 370mm, width × height × depth
Approx. Weight 24kg
Transport Feature Detachable high-voltage transformer
Fault Memory Stored fault and warning information for maintenance and diagnosis

Manufacturer Documentation

Download the OM2000A+ user manual, automatic-tuning guide, remote-control software, firmware loader, upgrade instructions and current firmware releases directly from OM Power.

View OM Power Downloads

Delivery Information

Shipping & Delivery

We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.

All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.

Same-Day Despatch

UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.

Weekend Delivery

Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.

Delivery Service Availability

Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.

Returns Information

Returns & Cancellations

To arrange a return, please contact our team at [email protected] or call 0345 2300 599.

Download Returns Form

Changed Your Mind?

Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.

Cancellation Period

14 Days

Notify us of your cancellation within 14 days of receiving your goods.

Once you have notified us, you have a further 14 days to return the goods.

Condition of Returned Goods

Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.

You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.

Important Conditions

Returns Exceptions

The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.

Modified Equipment & Reversal Charges

Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.

ML&S may charge a reasonable fee to reverse physical modifications and restore equipment to its original factory specification. Any applicable charge will be agreed in advance and deducted from your refund.

Custom-Made Cable Assemblies

Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.

Software & Labour Charges

Customer-requested labour and modification charges are non-refundable once the work has been completed.

Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.

Postage Options

Return Postage Charges

Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.

Standard Parcels

Royal Mail Return Label

£5.95

Per parcel

Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.

Larger Parcels

DPD Return Label

£7.95

Per parcel

Suitable for larger or heavier parcels, including shipments containing batteries.

Collection Service

DPD Collection

£25.00

Per parcel

Available upon request for eligible addresses, subject to service availability.

Return Postage Information

All prepaid return charges will be confirmed before booking and deducted from your refund.

The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.

Faulty or Incorrectly Supplied Goods

Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.

DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.

Refund Information

Refunds

How Refunds Are Processed

Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.

Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.

Product Support

Warranty Terms & Conditions

ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.

New Equipment

Minimum 2-Year Warranty

All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.

Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.

Used Equipment

3-Month Warranty

All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.

Warranty Repairs & Exclusions

Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.

Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.

All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.

Overseas Customers

International Returns & Warranty

Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.

International Return Conditions

International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.

ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.

We're Here to Help

Need Help With a Return?

Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.

Email ML&S

Alternatively, call us on 0345 2300 599.

Nothing in these terms excludes or limits your statutory consumer rights.