OM Power OM4001A 4kW Automatic HF Linear Amplifier
SKU Part Number: OM-4001A
Custom OM Power Control Cable Would You Like a Custom Control Cable Made? ...
Read More
£6,999.00
Pre Order
call

Seen this product cheaper elsewhere?

Call 0345 2300 599
Custom OM Power Control Cable

Would You Like a Custom Control Cable Made?

Select your radio manufacturer and model below, then click the button to send our team the details of your station.

Can't find your radio? Contact us at [email protected] and let us know which transceiver you would like to use.
4kW+ Fully Automatic HF Amplifier

OM Power OM4001A

A fully automatic dual-FU728F ceramic-tetrode HF linear amplifier delivering more than 4kW in SSB and CW, with automatic band switching, frequency-aware PA tuning, CAT integration, LAN remote control and comprehensive protection.

SSB / CW OUTPUT
4,000W+
High-power HF output across the amateur bands.
RTTY / DIGITAL
3,000W
Manufacturer-rated output for higher-duty-cycle modes.
POWER STAGE
2 × FU728F
Two high-power ceramic tetrodes.
DRIVE POWER
Typically 40-60W
Approximately 17dB power gain.
High Power Without Manual Retuning

A 4kW-Class Valve Amplifier That Follows the Radio

The OM Power OM4001A combines the RF performance of a high-power ceramic-tetrode amplifier with automatic control normally associated with modern solid-state designs.

Once configured for the station, CAT, CI-V, band-data or RF-sensing information can be used to select the correct band and stored tuning condition automatically as the operator changes frequency.

Dual Ceramic Tetrodes

Two FU728F Power Tubes

The OM4001A uses two FU728F ceramic tetrodes to deliver more than 4kW output in SSB and CW, with 3kW specified for RTTY and digital modes.

Automatic bias setup simplifies servicing following tube replacement, with the amplifier able to establish the required anode-current bias automatically.

Automatic PA Tuning

Frequency-Aware Tuning by Band Segment

Rather than requiring the operator to manually adjust TUNE and LOAD controls whenever frequency is changed, the OM4001A stores and recalls amplifier tuning conditions according to the selected band and frequency segment.

OM Power specifies a response time of less than 0.5 seconds when moving within the same band and less than 2 seconds when changing band.

Automatic Tune Explained

Automatic Amplifier Tuning, Not an Antenna Tuner

The automatic tuning system adjusts the amplifier's own tuned RF output network. It is not a wide-range antenna matching unit, so the antenna system, feeder and switching equipment must still present a suitable load and be rated for the RF power being used.

Fully Automatic Control

CAT, CI-V, Band Data or RF Sensing

OM Power provides direct integration with Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio 6xxx and Apache Labs ANAN equipment, together with Icom CI-V data supplied through compatible microHAM devices.

For transceivers without suitable CAT data, RF-sensitive band and frequency detection allows the OM4001A to provide automatic band switching without requiring a digital radio interface.

10 ANTENNAS
BCD Antenna Control
The amplifier can control up to ten external antenna-switch positions through BCD output data.
BAND DATA
External Filter Control
Yaesu-compatible BCD band data can automatically control suitable external band-pass filters.
OM6BPF
Automatic BPF Control
The optional OM Power OM6BPF can be switched automatically by compatible OM Power automatic amplifiers.
RF SENSING
CAT Not Essential
Automatic RF frequency detection provides an alternative for radios without compatible CAT control.
High Power Gain

Full Output from Around 40-60W Drive

With approximately 17dB power gain, the OM4001A normally requires only around 40 to 60W of transceiver drive to achieve full rated output, depending on frequency, tuning and load conditions.

RF Performance

High-Power Output with Controlled Distortion

OM Power specifies intermodulation distortion at approximately -32dB below nominal output, with harmonic suppression better than -50dBc.

Input impedance is 50 ohms with input VSWR below 1.5:1, while the output connection is an unbalanced 50-ohm system.

Load Protection

Automatic SWR Protection

Maximum specified output SWR is 3:1. If reflected power reaches approximately 350W or higher, the amplifier automatically switches to STBY to protect the RF stage.

At this level of RF power, antennas, feeders, connectors, switches, filters and other accessories must all be rated appropriately for the intended operating power.

Comprehensive Protection

Monitoring the Entire Power Amplifier

The OM4001A monitors SWR, anode current and voltage, screen current and voltage, grid current and voltage, heater voltage, amplifier tuning and operating temperature.

A soft-start system reduces mains inrush stress, while a safety interlock prevents normal switch-on with the amplifier opened. Faults and warnings are stored in memory to simplify diagnosis and servicing.

QSK
Full Break-In
Full QSK operation is supported for operators requiring rapid transmit and receive switching.
COOLING
Dual Blower System
A centrifugal blower and additional axial blower manage the substantial heat generated during high-power operation.
DISPLAY
4.3in Colour Touchscreen
Operating parameters, tuning information, status, warnings and stored faults are presented on the front-panel display.
Cooling Control

Three Programmable Axial-Blower Modes

Axial blower behaviour can be configured according to operating requirements, allowing cooling performance to be tailored to the expected workload.

Built-In LAN Control

Remote Control over the Network

The OM4001A incorporates a Lantronix XPORT network interface for remote monitoring and operation using OM Power's Windows remote-control software.

The factory network configuration can be changed through the XPORT web interface. OM Power recommends securing the interface with a username and password after installation.

High-Power Mains Supply

Dual 3kVA Toroidal Transformers

The OM4001A uses two 3kVA toroidal mains transformers. OM Power specifies switchable primary settings of 220/230/240V at 50Hz or 230/240/250V at 60Hz, with other primary-voltage arrangements available for certain markets.

A 4kW-class amplifier places substantial demands on the mains supply. Installation must be suitable for the amplifier and carried out in accordance with OM Power's instructions and applicable electrical regulations.

WIDTH
485mm
Substantial high-power amplifier chassis.
HEIGHT
200mm
Allow additional space for unobstructed cooling airflow.
DEPTH
455mm
Allow additional rear clearance for cables and ventilation.
WEIGHT
Approx. 46kg
Requires a suitably strong and stable operating position.
Operating Power

Use Within Your Licence Conditions

The OM4001A's maximum RF capability may exceed the transmit power permitted by an operator's amateur-radio licence. Output power must always be set and operated within the applicable licence conditions and local regulations.

Manuals, Firmware & Remote Software

OM4001A Downloads

OM Power provides the OM4001A instruction manual, automatic-tuning documentation, firmware updates, firmware loader and Windows remote-control software through its official download centre.

View OM Power Downloads
Technical Specification

OM Power OM4001A

Fully automatic HF linear amplifier using two FU728F ceramic tetrodes, with CAT and RF-sensed band control, automatic PA tuning, LAN remote control and comprehensive protection.

Amplifier Type Fully automatic ceramic-tetrode HF linear amplifier
Frequency Coverage Amateur bands from 1.8 to 29.7MHz including WARC bands
SSB / CW Output 4,000W+
RTTY / Digital Output 3,000W
Typical Drive Power Approximately 40-60W for full output
Power Gain 17dB
Input Impedance 50 ohms
Input VSWR Less than 1.5:1
Output Impedance 50 ohms unbalanced
Maximum Output SWR 3:1
SWR Protection Automatic STBY when reflected power reaches 350W or higher
Intermodulation Distortion -32dB below nominal output
Harmonic Suppression Better than -50dBc

RF Power Stage & Automatic Tuning

Power Tubes 2 × FU728F ceramic tetrode
Automatic Tuning Automatic band and frequency-segment PA tuning
Same-Band Response Less than 0.5 seconds
Band-Change Response Less than 2 seconds
Automatic Bias Automatic anode-current bias setup following tube replacement
Automatic Radio Control CAT, Icom CI-V, Yaesu-compatible band data and RF frequency sensing
Supported Manufacturers Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio 6xxx and Apache Labs ANAN
microHAM Compatibility Icom transceive / CI-V output from compatible microHAM interfaces
RF Sensing Automatic band and frequency detection where CAT data is unavailable
Band-Pass Filter Control Yaesu-compatible BCD BAND DATA output
External Antenna Control BCD control for up to 10 antenna positions
QSK Full break-in operation

Protection & Monitoring

VSWR too high
Anode current too high
Anode voltage error
Screen current too high
Screen voltage error
Grid current too high
Grid voltage error
Heater voltage error
PA mistuning
Temperature too high
Soft-start protection
Open-cover switch-on interlock
Power Supply High-voltage mains supply using two 3kVA toroidal transformers
50Hz Primary Settings 220 / 230 / 240V
60Hz Primary Settings 230 / 240 / 250V
Transformers 2 × 3kVA toroidal transformers
Cooling Centrifugal blower plus axial blower

LAN Remote Control

Network Interface Lantronix XPORT XP1001000-05R
Factory IP Address 192.168.1.222
Factory Subnet Mask 255.255.255.0
Factory Gateway 192.168.1.1
Remote Software Ports LAN ports 9999 and 10001 must be accessible for OM Power remote-control software
Display 4.3in colour touchscreen
Dimensions 485 × 200 × 455mm, width × height × depth
Approx. Weight 46kg
Fault Memory Fault and warning history stored for maintenance and diagnosis
Axial Blower Control Three programmable operating modes

Manufacturer Documentation

Download the current OM4001A manual, automatic-tuning instructions, remote-control software, firmware loader and firmware releases directly from OM Power.

View OM Power Downloads

Delivery Information

Shipping & Delivery

We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.

All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.

Same-Day Despatch

UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.

Weekend Delivery

Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.

Delivery Service Availability

Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.

Returns Information

Returns & Cancellations

To arrange a return, please contact our team at [email protected] or call 0345 2300 599.

Download Returns Form

Changed Your Mind?

Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.

Cancellation Period

14 Days

Notify us of your cancellation within 14 days of receiving your goods.

Once you have notified us, you have a further 14 days to return the goods.

Condition of Returned Goods

Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.

You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.

Important Conditions

Returns Exceptions

The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.

Modified Equipment & Reversal Charges

Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.

ML&S may charge a reasonable fee to reverse physical modifications and restore equipment to its original factory specification. Any applicable charge will be agreed in advance and deducted from your refund.

Custom-Made Cable Assemblies

Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.

Software & Labour Charges

Customer-requested labour and modification charges are non-refundable once the work has been completed.

Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.

Postage Options

Return Postage Charges

Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.

Standard Parcels

Royal Mail Return Label

£5.95

Per parcel

Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.

Larger Parcels

DPD Return Label

£7.95

Per parcel

Suitable for larger or heavier parcels, including shipments containing batteries.

Collection Service

DPD Collection

£25.00

Per parcel

Available upon request for eligible addresses, subject to service availability.

Return Postage Information

All prepaid return charges will be confirmed before booking and deducted from your refund.

The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.

Faulty or Incorrectly Supplied Goods

Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.

DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.

Refund Information

Refunds

How Refunds Are Processed

Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.

Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.

Product Support

Warranty Terms & Conditions

ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.

New Equipment

Minimum 2-Year Warranty

All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.

Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.

Used Equipment

3-Month Warranty

All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.

Warranty Repairs & Exclusions

Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.

Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.

All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.

Overseas Customers

International Returns & Warranty

Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.

International Return Conditions

International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.

ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.

We're Here to Help

Need Help With a Return?

Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.

Email ML&S

Alternatively, call us on 0345 2300 599.

Nothing in these terms excludes or limits your statutory consumer rights.