OM Power OM2501A 2.5kW Automatic HF Linear Amplifier with GU84B
SKU Part Number: OM-2501A-GU84B
Custom OM Power Control Cable Would You Like a Custom Control Cable...
Read More
Special Price £5,250.00 Regular Price £5,899.96
Availability: In stock
call

Seen this product cheaper elsewhere?

Call 0345 2300 599
Custom OM Power Control Cable

Would You Like a Custom Control Cable Made?

Select your radio manufacturer and model below, then click the button to send our team the details of your station.

Can't find your radio? Contact us at [email protected] and let us know which transceiver you would like to use.
Selecting a radio does not guarantee that a custom cable can be produced. Our team will confirm the required connections and compatibility before taking an order.
2.5kW Fully Automatic HF Amplifier

OM Power OM2501A

A fully automatic 2.5kW HF linear amplifier equipped with a GU84B ceramic tetrode, with CAT integration, RF frequency sensing, automatic PA tuning, external antenna and filter control, LAN remote operation and full QSK.

SSB / CW OUTPUT
2,500W
Automatic high-power HF operation.
RTTY / FM
2,000W
Manufacturer-rated high-duty-cycle output.
POWER STAGE
1 × GU84B
High-power ceramic tetrode.
AUTO TUNE
<0.5s / <2s
Same-band and band-change response respectively.
Automatic 2.5kW HF Power

Change Frequency. The Amplifier Follows.

The OM Power OM2501A covers the HF amateur bands from 1.8 to 29.7MHz, including WARC allocations, and is designed for fully automatic high-power station operation.

CAT communication or RF frequency sensing allows the amplifier to determine the operating frequency, select the correct band and recall the appropriate stored tuning condition automatically.

GU84B Ceramic Tetrode

Proven High-Power Valve Technology

This ML&S version of the OM2501A is supplied with a single GU84B ceramic tetrode.

The GU84B RF stage delivers up to 2,500W in SSB and CW, with 2,000W in RTTY and FM, while retaining the fully automatic tuning and protection systems of the OM2501A platform.

Automatic PA Tuning

Stored Tuning by Frequency Segment

The OM2501A automatically recalls amplifier tuning conditions according to the selected band and frequency segment, removing the need to manually retune the output network whenever the operating frequency changes.

OM Power specifies a response time of less than 0.5 seconds when moving within the same band and less than 2 seconds when changing bands.

Automatic Tune Explained

Automatic Amplifier Tuning, Not an Antenna Tuner

The automatic tuning system adjusts the amplifier's own tuned RF output network. It does not replace an external antenna matching unit, so the antenna system, feeder, switches and connectors must still present an appropriate high-power load.

Fully Automatic Control

CAT or RF Frequency Sensing

OM Power specifies compatibility with Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio 6xxx and Apache Labs ANAN, together with Icom CI-V data supplied through compatible microHAM interfaces.

Where suitable CAT data is unavailable, the amplifier can detect transmitted RF and use that information for automatic band and frequency switching.

AUTO BAND
Automatic Band Switching
The correct amplifier band is selected automatically from CAT or detected RF frequency information.
AUTO TUNE
Frequency-Segment Memory
Stored tuning positions are recalled automatically as operating frequency changes.
BAND DATA
External Filter Control
Yaesu-compatible BCD band-data output can switch suitable external band-pass filtering automatically.
ANTENNA CONTROL
Up to 10 Positions
BCD output can control a compatible external antenna switch with up to ten antenna positions.
High Power Gain

Full Output from Around 30-60W Drive

With approximately 17dB power gain, the OM2501A typically requires around 30 to 60W of RF drive for full rated output, depending on frequency, tuning and load conditions.

Station Integration

Automatic External Band-Pass Filter Control

The OM2501A provides band-data output for automatic control of compatible external band-pass filtering, making it particularly useful in contest and multi-radio installations.

The optional OM Power OM6BPF supports automatic switching from compatible OM Power automatic amplifiers.

RF Performance

Clean High-Power HF Output

OM Power specifies intermodulation distortion at better than -32dBc.

Harmonic suppression is specified at better than -50dBc.

Load Protection

Automatic Reflected-Power Protection

Maximum specified output SWR is 3:1. If reflected power reaches approximately 350W or higher, the amplifier automatically switches to STBY.

Input impedance is 50 ohms, with input VSWR specified below 1.5:1.

Comprehensive Protection

Monitoring the Complete Power Amplifier

The OM2501A monitors SWR, anode current and voltage, screen current and voltage, grid current and voltage, heater voltage, PA tuning and operating temperature.

Soft-start circuitry limits mains inrush and a cabinet safety interlock prevents normal switch-on while the amplifier is open. Faults and warnings are stored in memory to aid diagnosis and maintenance.

VSWR too high
Anode current too high
Anode voltage error
Screen current too high
Screen voltage error
Grid current too high
Grid voltage error
Heater voltage error
PA mistuning
Temperature too high
Soft-start protection
Open-cover switch-on interlock
QSK
Full Break-In
Full QSK operation is supported for rapid CW transmit and receive switching.
COOLING
Dual Blower System
Centrifugal and axial blowers provide forced-air cooling for the GU84B tube and power supply.
DISPLAY
4.3in Colour Touchscreen
Operating parameters, tuning status, warnings and amplifier conditions are displayed clearly at the front panel.
Easier Tube Replacement

Automatic Bias Setup

Following replacement of the GU84B tube, the OM2501A can automatically establish the required anode-current bias, avoiding the need for a separate manual bias-adjustment procedure.

Built-In LAN Control

Remote Monitoring and Control

The OM2501A incorporates a Lantronix XPORT network interface for remote monitoring and control using OM Power's Windows software.

Factory network settings are 192.168.1.222 with subnet mask 255.255.255.0 and gateway 192.168.1.1. LAN ports 9999 and 10001 must be accessible for the remote-control software.

High-Power Mains Supply

Two 2kVA Toroidal Transformers

The OM2501A uses two 2kVA toroidal transformers. Primary-voltage settings are switchable between 220/230/240V at 50Hz and 230/240/250V at 60Hz.

Other primary-voltage arrangements may be available for specific markets. The electrical installation must be suitable for the amplifier's mains demand and comply with OM Power's instructions and applicable electrical regulations.

WIDTH
485mm
Full-size high-power automatic amplifier chassis.
HEIGHT
200mm
Allow sufficient clearance for cooling airflow.
DEPTH
455mm
Allow additional rear space for cabling and ventilation.
WEIGHT
Approx. 40kg
Requires a suitably strong and stable operating position.
Operating Power

Use Within Your Licence Conditions

The OM2501A's maximum RF capability may exceed the transmit power permitted by an operator's amateur-radio licence. Output power must always be set and operated within applicable licence conditions and local regulations.

Manuals, Firmware & Remote Software

OM2501A Downloads

OM Power provides the OM2501A user manual, automatic-tuning guide, remote-control software, firmware loader, firmware-upgrade instructions and current firmware through its official download centre.

View OM Power Downloads
Technical Specification

OM Power OM2501A GU84B

Fully automatic 2.5kW HF linear amplifier equipped with a GU84B ceramic tetrode, CAT and RF frequency detection, automatic PA tuning, LAN remote operation, external antenna control and full QSK.

Amplifier Type Fully automatic GU84B ceramic-tetrode HF linear amplifier
Frequency Coverage Amateur bands 1.8-29.7MHz including WARC bands
SSB / CW Output 2,500W
RTTY / FM Output 2,000W
Drive Power 30-60W for full output
Power Gain 17dB
Input Impedance 50 ohms
Input VSWR Less than 1.5:1
Output Impedance 50 ohms unbalanced
Maximum Output SWR 3:1
SWR Protection Automatic STBY at approximately 350W reflected power or higher
Intermodulation Distortion Better than -32dBc
Harmonic Suppression Better than -50dBc

RF Power Stage & Automatic Tuning

Tube 1 × GU84B ceramic tetrode
Automatic Tuning Automatic band and frequency-segment PA tuning
Same-Band Response Less than 0.5 seconds
Band-Change Response Less than 2 seconds
Automatic Bias Setup Supported following GU84B tube replacement
QSK Full break-in operation
Automatic Radio Control CAT plus RF-sensitive frequency detection
Supported CAT Manufacturers Icom, Yaesu, Kenwood, Elecraft, Ten-Tec Orion, FlexRadio 6xxx and Apache Labs ANAN
microHAM Compatibility Icom CI-V output from compatible microHAM devices
RF Frequency Detection Automatic band and frequency switching where CAT is unavailable
Band-Pass Filter Control Yaesu-compatible BCD band-data output
External Antenna Control BCD control for up to 10 external antenna positions

Protection & Monitoring

VSWR too high
Anode current too high
Anode voltage error
Screen current too high
Screen voltage error
Grid current too high
Grid voltage error
Heater voltage error
PA mistuning
Temperature too high
Soft-start protection
Open-cover switch-on interlock
Power Supply High-voltage mains supply using two 2kVA toroidal transformers
50Hz Primary Settings 220 / 230 / 240V
60Hz Primary Settings 230 / 240 / 250V
Transformers 2 × 2kVA toroidal transformers
Cooling Centrifugal blower plus axial blower
Display 4.3in colour touchscreen
LAN Interface Lantronix XPORT XP1001000-05R
Factory IP Address 192.168.1.222
Factory Subnet Mask 255.255.255.0
Factory Gateway 192.168.1.1
Remote Software LAN Ports 9999 and 10001
Dimensions 485 × 200 × 455mm, width × height × depth
Approx. Weight 40kg
Fault Memory Stored faults and warnings for maintenance and diagnosis
Cooling Modes Three programmable operating modes for the axial blower

Manufacturer Documentation

Download the OM2501A user manual, automatic-tuning guide, remote-control software, firmware loader, firmware-upgrade instructions and current firmware directly from OM Power.

View OM Power Downloads

Delivery Information

Shipping & Delivery

We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.

All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.

Same-Day Despatch

UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.

Weekend Delivery

Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.

Delivery Service Availability

Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.

Returns Information

Returns & Cancellations

To arrange a return, please contact our team at [email protected] or call 0345 2300 599.

Download Returns Form

Changed Your Mind?

Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.

Cancellation Period

14 Days

Notify us of your cancellation within 14 days of receiving your goods.

Once you have notified us, you have a further 14 days to return the goods.

Condition of Returned Goods

Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.

You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.

Important Conditions

Returns Exceptions

The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.

Modified Equipment & Reversal Charges

Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.

ML&S may charge a reasonable fee to reverse physical modifications and restore equipment to its original factory specification. Any applicable charge will be agreed in advance and deducted from your refund.

Custom-Made Cable Assemblies

Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.

Software & Labour Charges

Customer-requested labour and modification charges are non-refundable once the work has been completed.

Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.

Postage Options

Return Postage Charges

Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.

Standard Parcels

Royal Mail Return Label

£5.95

Per parcel

Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.

Larger Parcels

DPD Return Label

£7.95

Per parcel

Suitable for larger or heavier parcels, including shipments containing batteries.

Collection Service

DPD Collection

£25.00

Per parcel

Available upon request for eligible addresses, subject to service availability.

Return Postage Information

All prepaid return charges will be confirmed before booking and deducted from your refund.

The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.

Faulty or Incorrectly Supplied Goods

Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.

DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.

Refund Information

Refunds

How Refunds Are Processed

Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.

Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.

Product Support

Warranty Terms & Conditions

ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.

New Equipment

Minimum 2-Year Warranty

All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.

Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.

Used Equipment

3-Month Warranty

All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.

Warranty Repairs & Exclusions

Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.

Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.

All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.

Overseas Customers

International Returns & Warranty

Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.

International Return Conditions

International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.

ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.

We're Here to Help

Need Help With a Return?

Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.

Email ML&S

Alternatively, call us on 0345 2300 599.

Nothing in these terms excludes or limits your statutory consumer rights.