Read More

Seen this product cheaper elsewhere?
Call 0345 2300 599A new generation can be found with the ACOM 1003 is an autonomous and independent linear amplifier that covers all amateur radio bands from 1.8 MHz to 54 MHz. It delivers 1000 W power output PEP or 900 W continuous carrier with no limitation to the operating mode, with 50-80 W input power (from the transceiver).
Easy to operate
Antenna setup is made simple by a bar indicator for accurate setting of the actual load resistance at the tube anode (TRI). An operator-controlled input attenuator allows for an easy decrease of input power, without the need for transceiver adjustments. Peak power bar indicator, operational parameters and text messages are displayed during operation on a two-line OLED display. Switching receive/transmit is fast and OSK compatible, using a silent HF reed relay.
No external antenna tuner needed
No need for an external antenna tuner (ATU) for antenna SWR up to 3:1. A SWR up to 3:1 is allowed at 1000 W output to the antenna.
User-friendly and durable
An amplifier that is both user-friendly and that looks after itself.
- Operator selectable class AB2 mode for best linearity or class B for minimal loss at the anode in continuous digital modes;
- Operator selectable modes of full or 50% reduced power output with no decrease in efficiency;
- Auto-controlled cooling airflow;
- Continuous monitoring of parameters and tube protection;
- Able to monitor 20 operator selectable amplifier parameters on the display;
- Unique ACOM protection for the band's switch (BAND);
- Original ACOM HF arc protection at the output, or at the antenna;
- Original ACOM TRI prompt: bar indicator for quick and accurate setting of the actual load resistance at the tube anode when matched to the antenna;
- Factory preset input lowpass filters for best linearity and input SWR less than 1.3 for any amateur radio band;
OLED comment display
Two-line OLED display peak bar indicator for the output power, 20 operational parameters and detailed text messages. All amplifier status indications are explained via detailed text displayed on the OLED display.
Three antenna outputs
Three antenna outputs are selectable using a push-button on the front panel.
Less noise in the shack
HF antenna reed relay for a virtually no noise operation, QSK compatible CW operation.
Transceiver-independent
The amplifier operates without special signals from the transceiver - "Ground on TX" (PTT) and 80 W RF drive power are sufficient.
Single tube operation
Uses a single 3CX800A7 cermet triode in a grounded grid loop.
Tube protection
Continuous monitoring of parameters and tube protection.
Output RF arc protection
Original ACOM HF arc protection at the output, or at the antenna.
Power supply
Single phase mains power, 90-132 / 180-264 VAC at 50-60 Hz, power consumption at rated output – 2000 VA, cosϕ=0.8 @ 240 VAC. The amplifier power supply can be configured for 8 different nominal line voltages: 100, 110, 120, 200, 210, 220, 230, or 240 VAC.
Easy maintenance
Non-volatile memory with SIGNATURES of the most recent 8 Serious Fault Protection events.
You can download the user manual HERE
Frequency Coverage
- All amateur bands from 1.8 through 54 MHz:
- 1.800 - 2.000 MHz (160 m band)
- 3.500 - 4.000 MHz (80 m band)
- 5.250 - 5.450 MHz (60 m band)*
- 7.000 - 7.300 MHz (40 m band)
- 10.100 - 10.150 MHz (30 m band)
- 14.000 - 14.350 MHz (20 m band)
- 18.068 - 18.168 MHz (17 m band)
- 21.000 - 21.450 MHz (15 m band)
- 24.890 - 24.990 MHz (12 m band)
- 28.000 - 29.700 MHz (10 m band)
- 50.000 - 54.000 MHz (6 m band)*
- (*) Please, refer to the applicable regional band plans and laws for specific allocations and limitations;
- In specific business cases, extensions or changes of the frequency coverage can be discussed, but this must be agreed upon before ordering. In any case, this is not the producer's obligation and can not be against local rules and laws.
Power Output
- 1000 W PEP or 900 W continuous carrier, with no limitation to the operating mode;
- In continuous carrier modes (RTTY etc.) for transmissions longer than 5 minutes, the external auxiliary fan must be mounted;
Intermodulation Distortion at rated power
- No more than 34 dB IMD3 with regard to one of the two tones (40 dB with regard to PEP);
Electric hum and noise
- No more than 40 dB at rated power;
Harmonic Emissions Output Suppression
- 1.8-29.7 MHz - no less than 50 dB below rated power;
- 50-54 MHz - no less than 70 dB below rated power;
Input and Output Impedances
- 50 Ohm asymmetric, UHF coaxial connectors (SO-239A);
- Input circuit: factory setup low-pass filters for a high level of linearity and input SWR no more than 3:1 in every HAM radio frequency band from 160 m to 6 m;
- Bypass section SWR: No more than 1.1 continuously from 1.8 MHz to 54 MHz;
- Range of matched output impedances: SWR to 3 at an arbitrary phase angle;
HF Gain
- 12 dB ±1 dB (50-80 W at the input for rated output power);
Mains Power Supply Voltage
- 90-132 / 180-264 VAC (100, 110, 120, 200, 210, 220, 230 or 240 VAC nominal taps, ±10% tolerance), 50-60 Hz, Single phase;
Mains Power Consumption
- 2000 VA at rated output, cosϕ=0.8 @ 240 VAC;
Safety and Electromagnetic Compatibility
- Complies with CE safety and electromagnetic compatibility requirements, as well as with the US Federal Communications Commission (FCC) regulations;
Size & Weight (operating, excluding connected cables)
- WxDxH: 423x398x195 mm, 21.0 kg (16.7x15.7x7.7 inches, 46.3 lbs.);
Shipping Size & Weight
- WxDxH: Approx. 632x583x413 mm, 25.0 kg (24.9x23.0x16.3 inches, 55.2 lbs.);
Operating environments
- Temperature range: 0 to +50 degrees Celsius (32 degrees F to 122 degrees F);
- Relative air humidity: up to 95% @ +35 degrees Celsius (95 degrees F);
- Height above sea level: up to 3050 m (10000 ft) without output deterioration.
Delivery Information
Shipping & Delivery
We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.
All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.
Same-Day Despatch
UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.
Weekend Delivery
Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.
Delivery Service Availability
Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.
Returns Information
Returns & Cancellations
To arrange a return, please contact our team at [email protected] or call 0345 2300 599.
Download Returns FormChanged Your Mind?
Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.
Cancellation Period
14 Days
Notify us of your cancellation within 14 days of receiving your goods.
Once you have notified us, you have a further 14 days to return the goods.
Condition of Returned Goods
Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.
You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.
Important Conditions
Returns Exceptions
The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.
Postage Options
Return Postage Charges
Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.
Standard Parcels
Royal Mail Return Label
£5.95
Per parcel
Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.
Larger Parcels
DPD Return Label
£7.95
Per parcel
Suitable for larger or heavier parcels, including shipments containing batteries.
Collection Service
DPD Collection
£25.00
Per parcel
Available upon request for eligible addresses, subject to service availability.
Return Postage Information
All prepaid return charges will be confirmed before booking and deducted from your refund.
The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.
Faulty or Incorrectly Supplied Goods
Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.
DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.
Refund Information
Refunds
How Refunds Are Processed
Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.
Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.
Product Support
Warranty Terms & Conditions
ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.
New Equipment
Minimum 2-Year Warranty
All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.
Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.
Used Equipment
3-Month Warranty
All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.
Warranty Repairs & Exclusions
Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.
Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.
All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.
Overseas Customers
International Returns & Warranty
Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.
International Return Conditions
International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.
ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.
We're Here to Help
Need Help With a Return?
Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.
Email ML&SAlternatively, call us on 0345 2300 599.
Nothing in these terms excludes or limits your statutory consumer rights.



