Messi & Paoloni ULTRAFLEX 10/C Outpost Coax Cable
SKU Part Number: RG-MP-UF10-C-GREEN
Green 10.3mm Competition-Grade Low-Loss Coax Messi & Paoloni ULTRAFLEX...
Read More
£3.65
Availability: In stock
call

Seen this product cheaper elsewhere?

Call 0345 2300 599
Green 10.3mm Competition-Grade Low-Loss Coax

Messi & Paoloni ULTRAFLEX 10/C Outpost /.400"

Premium flexible 50 ohm coax with far lower loss than conventional RG213/U and dramatically lower loss than RG-8X, finished in a discreet UV-resistant green jacket.

Try our Custom Coax Builder

Choose your cable length and connector combination and let us build the lead for you.

Ordering 100 metres or more? Save 10% on the cable.
Serious RF Performance

Far lower loss than RG213. Dramatically lower loss than RG-8X.

ULTRAFLEX 10/C Outpost combines premium 10.3mm coax performance with exceptional flexibility, full-copper RF construction and a UV-resistant green outer jacket.

Messi & Paoloni ULTRAFLEX 10/C Outpost /.400" is a high-performance 10.3mm 50 ohm coaxial cable combining very low attenuation with the flexibility of a stranded copper centre conductor.

Compared with conventional RG213/U, ULTRAFLEX 10/C Outpost delivers substantially lower feed-line loss from a cable of almost identical overall diameter. Its modern physically foamed dielectric, 87% velocity factor and full-copper screening system give it a considerable performance advantage.

Against RG-8 Mini / RG-8X, the improvement is even more dramatic. RG-8X may be convenient and relatively flexible, but its attenuation rises quickly as frequency and cable length increase. ULTRAFLEX 10/C Outpost retains far more of your transmitted power and received signal.

PERFORMANCE
Far Better Than RG213

Substantially lower attenuation than conventional RG213/U while remaining in the same general 10mm cable class.

UPGRADE
Huge Upgrade from RG-8X

Dramatically lower loss than typical RG-8X, particularly on longer VHF and UHF feed lines.

OUTPOST
Green Outer Jacket

UV-resistant green PVC is less visually conspicuous around gardens, vegetation and outdoor antenna installations.

VELOCITY FACTOR
87%

Triple-layer physically foamed polyethylene dielectric provides excellent RF performance across a wide frequency range.

Outpost Green Jacket

The Outpost Version of ULTRAFLEX 10/C

What immediately distinguishes the Outpost version is its UV-resistant green PVC outer jacket.

This makes it particularly attractive for permanent outdoor antenna systems, garden installations and field stations where a green cable will blend more naturally into vegetation and surrounding landscaping than a conventional black or white feed line.

Beneath the green jacket is a sophisticated low-loss construction featuring a stranded copper centre conductor, triple-layer physically foamed dielectric, full copper foil screen and reactive copper braid.

Low-Loss Performance

Premium Low-Loss Performance

At 20°C, M&P specifies attenuation of only 1.4dB per 100m at 14MHz, 2.6dB at 50MHz, 4.6dB at 144MHz, 8.5dB at 430MHz and 15.3dB at 1296MHz.

This makes ULTRAFLEX 10/C Outpost particularly attractive for longer feed-line runs and higher-frequency operation where ordinary coaxial cable losses can quickly become a significant part of the station's overall performance.

Cable Comparison

See the Difference Against RG213 and RG-8X

Lower attenuation means more of your transmitted signal reaches the antenna and more of weak received signals reach your receiver.

Frequency ULTRAFLEX 10/C Outpost Typical RG213/U Typical RG-8X
50MHz 2.6dB / 100m Approx. 4.6dB / 100m Approx. 6.6dB / 100m
100MHz 3.8dB / 100m Approx. 6.6dB / 100m Approx. 9.8dB / 100m
400MHz 8.2dB / 100m Approx. 14.1dB / 100m Approx. 19.7dB / 100m

RG213/U and RG-8X figures are representative values and may vary between manufacturers and individual cable constructions.

Why Upgrade?

If you are currently using RG213, ULTRAFLEX 10/C Outpost can significantly reduce feed-line loss while remaining almost identical in overall cable diameter.

If you are replacing RG-8X, the performance improvement is substantially greater, particularly on 6m, 2m and 70cm where cable attenuation becomes increasingly important.

Flexible Construction

Low Loss Without Sacrificing Flexibility

ULTRAFLEX 10/C Outpost uses a 7 x 1.0mm stranded copper centre conductor with an overall diameter of approximately 2.9mm.

The stranded construction provides much greater flexibility than a comparable solid-centre low-loss cable, making it practical for tight cable routes and installations involving antenna rotators.

M&P specifies a minimum bend radius of 80mm for repeated bending up to 15 bends and only 40mm for a single bend or choke.

M&P Construction

Reactive Copper Braid

The outer conductor includes a 144-wire copper reactive braid with 71% coverage.

M&P manufactures the braid using a 24-spool machine rather than a conventional 16-spool process. The additional crossover points help provide exceptional screening while allowing the braid to react to twisting and bending in a spring-like manner.

Beneath the braid is a 100% copper foil first screen with an applied polyethylene layer designed to help prevent cracking during short-radius bends.

RF Isolation

Greater Than 105dB Screening

M&P specifies screening efficiency greater than 105dB between 100MHz and 2000MHz.

The full copper foil and reactive braid screening system helps minimise unwanted RF ingress and radiation from the feed line, making ULTRAFLEX 10/C Outpost well suited to demanding amateur radio and communications installations.

High-Power Operation

Excellent Power Handling

ULTRAFLEX 10/C Outpost is equally capable in demanding transmit installations. At a cable temperature of 40°C, M&P specifies continuous power handling of approximately 3428W at 14MHz, 1849W at 50MHz, 1049W at 144MHz and 587W at 430MHz.

Maximum Peak Power
12,000W Maximum Peak Power

M&P specifies a maximum peak-power rating of 12kW. Continuous power capability depends on frequency and cable temperature, so the detailed power-handling figures should be used when planning a high-power installation.

Applications

Where ULTRAFLEX 10/C Outpost Works Best

OUTDOOR
Outdoor Stations

Green outer jacket blends more naturally into gardens, vegetation and outdoor antenna installations.

BASE STATIONS
High-Performance Base Stations

Low attenuation and excellent screening make it a strong all-round feed line for demanding stations.

LONG RUNS
Long Feed Lines

Low attenuation helps preserve both transmitted power and weak received signals over substantial cable lengths.

VHF / UHF
VHF and UHF

Particularly worthwhile as frequency rises and feed-line losses become increasingly significant.

MOVEMENT
Rotator Antennas

Stranded copper construction and reactive braid provide excellent flexibility for beam antennas and rotator loops.

UPGRADE
Replacing RG213 or RG-8X

A substantial performance upgrade where reducing feed-line attenuation is a priority.

Cable Design

Cable Construction

  • 7 x 1.0mm stranded copper inner conductor
  • 2.9mm overall inner conductor diameter
  • Triple-layer high-pressure physically foamed polyethylene dielectric
  • 100% copper foil first screen with applied PE layer
  • 71% coverage reactive copper braid
  • 144 copper braid wires manufactured using 24 spools
  • UV-resistant green PVC outer jacket
  • 10.3mm overall cable diameter
  • 87% velocity factor
  • Screening efficiency greater than 105dB from 100 to 2000MHz
  • Maximum peak power 12,000W
Installation Note
Direct Burial Not Specified

The M&P datasheet specifies a UV-resistant green PVC outer jacket but does not state that ULTRAFLEX 10/C Outpost is suitable for direct burial.

Manufacturer Documentation

ULTRAFLEX 10/C Outpost Datasheet

View ULTRAFLEX 10/C Outpost Datasheet
Product Information

ULTRAFLEX 10/C Outpost /.400" Technical Specifications

Specifications

General

Official Model ULTRAFLEX 10/C Outpost /.400"
Nominal Impedance 50 ohms ±3 at 200MHz
Overall Diameter 10.3mm ±0.15mm
Velocity Factor 87%
Capacitance 78pF/m ±2
Screening Efficiency Greater than 105dB, 100 to 2000MHz
Operating Temperature -40°C to +60°C
Net Weight 13kg per 100m
Maximum Peak Power 12,000W
Spark Test 8kV
Cable Design

Construction

Inner Conductor 7 x 1.0mm copper wires
Inner Conductor Diameter 2.9mm ±0.15mm
Dielectric Triple-layer high-pressure physically foamed polyethylene
Dielectric Diameter 7.3mm ±0.05mm
First Screen 100% copper foil with applied PE layer
Reactive Braid 71% coverage, 144 copper wires, 24-spool construction
Outer Jacket UV-resistant green PVC
Inner Conductor Resistance 3.2 ohms/km
Outer Conductor Resistance 9.2 ohms/km
Flexibility

Minimum Bend Radius

Repeated Bending

80mm for up to 15 bends

Single Bend / Choke

40mm

Return Loss

Structural Return Loss

0.3 to 600MHz Greater than 30dB
600 to 1200MHz Greater than 25dB
1200 to 2000MHz Greater than 20dB
RF Loss

Attenuation at 20°C

Frequency Loss dB/100m
1.8MHz0.7dB
3.5MHz0.9dB
7MHz1.0dB
10MHz1.2dB
14MHz1.4dB
21MHz1.7dB
28MHz1.9dB
50MHz2.6dB
100MHz3.8dB
144MHz4.6dB
200MHz5.5dB
400MHz8.2dB
430MHz8.5dB
800MHz11.8dB
1000MHz13.3dB
1296MHz15.3dB
2400MHz21.7dB
3000MHz24.5dB
4000MHz29.0dB
5000MHz33.0dB
5800MHz34.9dB
6000MHz36.8dB
7000MHz40.6dB
8000MHz44.1dB
9000MHz48.1dB
10000MHz52.0dB
11000MHz55.8dB
12000MHz59.9dB
RF Power

Continuous Power Handling at 40°C

Frequency Maximum Continuous Power
1.8MHz6427W
3.5MHz5142W
7MHz4285W
10MHz3955W
14MHz3428W
21MHz2856W
28MHz2437W
50MHz1849W
100MHz1275W
144MHz1049W
200MHz883W
400MHz610W
430MHz587W
800MHz419W
1000MHz372W
1296MHz321W
2400MHz223W
3000MHz193W
4000MHz158W
5000MHz135W
6000MHz117W
7000MHz104W
8000MHz93W

Delivery Information

Shipping & Delivery

We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.

All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.

Same-Day Despatch

UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.

Weekend Delivery

Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.

Delivery Service Availability

Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.

Returns Information

Returns & Cancellations

To arrange a return, please contact our team at [email protected] or call 0345 2300 599.

Download Returns Form

Changed Your Mind?

Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.

Cancellation Period

14 Days

Notify us of your cancellation within 14 days of receiving your goods.

Once you have notified us, you have a further 14 days to return the goods.

Condition of Returned Goods

Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.

You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.

Important Conditions

Returns Exceptions

The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.

Modified Equipment & Reversal Charges

Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.

ML&S may charge a reasonable fee to reverse physical modifications and restore equipment to its original factory specification. Any applicable charge will be agreed in advance and deducted from your refund.

Custom-Made Cable Assemblies

Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.

Software & Labour Charges

Customer-requested labour and modification charges are non-refundable once the work has been completed.

Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.

Postage Options

Return Postage Charges

Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.

Standard Parcels

Royal Mail Return Label

£5.95

Per parcel

Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.

Larger Parcels

DPD Return Label

£7.95

Per parcel

Suitable for larger or heavier parcels, including shipments containing batteries.

Collection Service

DPD Collection

£25.00

Per parcel

Available upon request for eligible addresses, subject to service availability.

Return Postage Information

All prepaid return charges will be confirmed before booking and deducted from your refund.

The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.

Faulty or Incorrectly Supplied Goods

Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.

DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.

Refund Information

Refunds

How Refunds Are Processed

Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.

Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.

Product Support

Warranty Terms & Conditions

ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.

New Equipment

Minimum 2-Year Warranty

All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.

Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.

Used Equipment

3-Month Warranty

All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.

Warranty Repairs & Exclusions

Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.

Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.

All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.

Overseas Customers

International Returns & Warranty

Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.

International Return Conditions

International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.

ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.

We're Here to Help

Need Help With a Return?

Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.

Email ML&S

Alternatively, call us on 0345 2300 599.

Nothing in these terms excludes or limits your statutory consumer rights.