ACOM 06AT | Automatic Antenna Tuner and Switch
SKU Part Number: ACOM 06AT
UsageACOM 06AT is an automatic antenna tuner for HF + 6 m with integrated four-way antenna switch. The tuner automatically selects one of four...
Read More
£1,150.00 £958.33
Availability: In stock
call

Seen this product cheaper elsewhere?

Call 0345 2300 599

Usage
ACOM 06AT is an automatic antenna tuner for HF + 6 m with integrated four-way antenna switch. The tuner automatically selects one of four available antenna outputs (as assigned in bands by the operator) and matches the impedance of the chosen antenna output by transforming it to 50 Ohm with SWR below 1.5:1 at the tuner input (typically below 1.3), providing an optimum load impedance for the amplifier.

Compatibility
The ACOM 06AT tuner is specifically designed and developed to work exclusively with the ACOM series of solid state (transistor) amplifiers, e.g., ACOM 600S, 700S, 1200S or ACOM 2020S.

Easy set-up of user tuning presets
For a CAT transceiver a single press of the TUNE button on the amplifier front panel is all you need.

Transparent (invisible) operation
After setting up the user presets (auto tune) for the frequency segments and antennas, the operator will not be involved with tuner operation.

Three kinds of frequency segments, according to antenna natural bandwidth
The operator can choose according to the nature of each of the four antennas: Narrow band - Sharp, Normal - Regular, and Broadband - Wide.

Capability of operation at fixed frequencies
This capability is available also.

Non-volatile memory
Non-volatile memory for user presets (auto tune), independent for the four antennas, the three types of segment width, and more than 1000 random fixed frequencies for each antenna.

User presets
The user presets are automatically loaded, following frequency and antenna selection changes.

Export (backup) of preset memory
Backup of preset memory to a computer file, import of previously made backup files from a computer to the tuner memory.

Helpful information
Information about the setting age, and alerts for settings that reach a certain age, defined by the operator in 4 possible age levels.

Power supply and control to the tuner
Power supply and control to the tuner, as well as status return from the tuner are facilitated over the coaxial cable between the amplifier and tuner, no need for additional cables or special control signals from the transceiver (the availability of CAT control from the transceiver will give further advantages to the setup).

Improved electromagnetic compatibility
Full tuning can be completed within 5 seconds (typically 2-3 seconds), at 25 W at the tuner input and less than 6 W at the antenna output; quick tuning (from nonvolatile-memory presets) is completed in less than 0.05 seconds with zero emitted signals.

Input SWR during full tuning cycles
Input SWR during full tuning cycles - below 2:1, preventing activation of transceiver PA protection.

Input SWR after completing a tuning cycle
Input SWR after completing a tuning cycle - below 1.5:1 (typically below 1.3:1).

Relays with gold-plated contacts
Relays with gold-plated contacts for excellent receive characteristics.

Relay switching
Relay switching will only take place when no RF current is flowing, preventing contact arcing critical for preventing contact oxidation, surface melting and material transfer (otherwise resulting in poor receiving performance) and to avoid any unwanted widening of the spectrum of signals, emitted during the tuning cycle.

Air-core coils and high-quality ceramic capacitors
Air-core coils (no magnetic materials) and high-quality NP0 (C0G) ceramic capacitors usage throughout the matching circuit.

Harmonic suppression
Improves harmonic suppression - the matching network is a low-pass L filter.

Saves space on the operating position
ACOM 06AT can be located up to 100 m (330 ft) away from the shack (in another room, but not outdoor).

Integrated antenna switch
Integrated four-way antenna switch - less coaxial cable, shorter unmatched sections, less losses.

Automatic and manual antenna switching
Antennas can be automatically and manually switched from the amplifier front panel. The last used antenna selection is memorized.

Customized antennas names and types
Indication and editing of names and types of antennas in editable freeform.

Protection mechanisms
Various protection mechanisms, including: antenna overvoltage, antenna overcurrent, excessive power during operation and tuning, extreme temperatures and power supply voltages, as well as relay hot-switching.

Safe power supply
Safe power supply voltage (26 VDC).

BYPASS mode
In BYPASS mode all components of the matching network are excluded, allowing direct operation of broadband antennas.

SERVICE menu
This menu allowing analysis of the tuner status and review of the used resource of coils and capacitors for all memorized and current tuning presets.

Lightning arrestor and bleeder resistor
Integrated lightning arrestor and bleeder resistor for protection against static discharges; automatic grounding of antennas on powering down.

Operating Frequency Range

  • Continuous from 1.8 to 30 and from 50 to 54 MHz;
  • Extensions and/or changes on request;

Minimum Range of the Matched Impedances (at Each of the Four Antenna Outputs)

  • All impedances with SWR from 1:1 to 3:1 towards 50 Ohm, any phase angle, unbalanced input and output;
  • For some frequencies and impedances, matching is possible at SWR above 3:1 at the antenna output (up to 10:1), but the maximum allowed power is reduced;

Maximum Allowed Input Power (PEP, Mean or Continuous Carrier, Without Mode Limitation)

  • At antenna SWR below 2.5: 1500 W;
  • At antenna SWR between 2.5 and 3: 1200 W;
  • At antenna SWR between 3 and 5 (provided matching is possible): 500 W;
  • At antenna SWR between 5 and 10 (provided matching is possible): 200 W;
  • Operation with SWR above 10:1 is not allowed;

RF Input Characteristics

  • Rated impedance: 50 Ohm unbalanced;
  • Input connector type: UHF/PTFE (SO-239A) - 1 pc.;
  • SWR during full tuning (basic cycle): No higher than 2:1;
  • SWR immediately after full tuning: No higher than 1.5:1 (1.3:1 typically);

Antenna Outputs Characteristics, Antenna 1 to Antenna 4

  • Rated impedance: 50 Ohm unbalanced;
  • Maximum antenna output SWR: 3:1 (up to 10:1 with RF power limitations);
  • Output connectors type: UHF/PTFE (SO-239A) - 4 pcs;

Full Tuning Duration (Basic Cycle)
Basic cycle for preparation of user full tuning settings, with automatic storage in the non-volatile memory:

  • In the range of 1.8 to 10 MHz: No more than 5 seconds (2-3 seconds typically);
  • In the range of 10 to 54 MHz: No more than 3 seconds (1-2 seconds typically);

Input Signal Needed to Prepare User Tuning Settings

  • Non-modulated carrier power 25 W +3/-3 dB (12.5 to 50 W);

Power Supply

  • +26 VDC, +10/-15%, consumption of 25 W at most;
  • Supplied by an amplifier of the ACOM transistor series over the input RF coaxial cable;

Remote Control

  • The remote control and indication from an amplifier of the ACOM transistor series is provided over the input RF coaxial cable of the tuner using a 60 kHz / 4800 bps bidirectional FSK modem;

Maximum Length of the Input Coaxial Cable

  • The maximum length of the RF coaxial cable between the amplifier output and the tuner input is 100 m (330 ft) for a cable of RG213 type or similar. The cable characteristic impedance should be 50 Ohm and the DC resistance should be below 1 Ohm for inner and outer conductors altogether;

Size & Weight (operating, excluding fastening elements and connected cables)

  • WxDxH: 212x312x158 mm, x.x kg (8.4x12.3x6.3 inches, x.x lbs.);

Shipping Size & Weight

  • WxDxH: Approx. 382x459x348 mm, x.x kg (15.1x18.1x9.8 inches, xx.x lbs.);
  • Please, contact us for shipment details;

Operating Environment

  • Temperature range: -10 to +40 degrees Celsius (14 degrees F to 104 degrees F);
  • Relative air humidity: Up to 95% @ +35 degrees Celsius (95 degrees F);
  • Height above sea level: up to 3050 m (10000 ft) without output deterioration.

ACOM 06AT Brochure | September 2022 | PDF file

ACOM 06AT User's Manual | October 2022 | PDF file

Shipping:

We have several shipping options for our products, including next-day and Saturday/Sunday delivery for certain items. Please see these options at checkout.

Returns:

If you have any equipment that needs to be returned to Martin Lynch & Sons, please fill out the form below:

Click here for returns form

Upon receipt of goods you have 14 days to return goods however the goods must be returned in original packaging and care must have been taken with the goods you wish to return. Under distance selling regulations you are not entitled to any refund on carriage charges or modification charges made at your request.

Warranty Terms and Conditions

Outside of the 14 faulty return period, returned items cannot be accepted, unless covered by manufacturer's warranty. We will repair as much as possible on site however in exceptional circumstances products may have to be returned to the manufacturer of distributor.

For repairs/replacements under manufacturer’s warranty for any item please download a ML&S return form from the link above and return to ML&S with the faulty product.

International Warranty information

Warranty service for items we sell is available in the U.K. only, unless otherwise noted. It is your responsibility to pay freight for returned items to the U.K. and back to you for desired warranty coverage. All of our NEW products come with a minimum 12 month warranty, (Yaesu & Icom 24 months), with up to 90 days on second-hand equipment. Items returned for service must state "returned goods for repair" on the return air waybill or U.K. import customs duties apply and will be added to your invoice. For more info about returning items please contact our customer help desk, [email protected]