Flexible 10.3mm Waterproof Direct-Burial Coax

Messi & Paoloni EXTRAFLEX BURY 10 /.400"

Premium low-loss 50 ohm coax combining excellent flexibility with a tough waterproof PE jacket for direct burial, outdoor installations, tight bends and rotator-operated antennas.

Try our Custom Coax Builder

Choose your cable length and connector combination and let us build the lead for you.

Ordering 100 metres or more? Save 10% on the cable.
Flexibility Meets Direct Burial

Low loss, waterproof, flexible and designed for permanent outdoor installation.

EXTRAFLEX BURY 10 combines a stranded copper centre conductor and reactive braid with a tear-resistant polyethylene jacket and protective petrol-jelly layer.

Messi & Paoloni EXTRAFLEX BURY 10 /.400" is a high-performance 10.3mm coaxial cable designed for installations where you need both excellent flexibility and genuine outdoor durability.

M&P specifically positions EXTRAFLEX BURY 10 as a cable capable of handling outdoor use, direct burial, tight bends and rotator-operated antennas within the same design.

Its low-loss RF construction uses a stranded copper centre conductor, physically foamed dielectric, full copper foil screen and dense reactive braid, while the outside of the cable is protected by a UV-resistant polyethylene jacket and a petrol-jelly layer designed to help prevent oxidation and improve water resistance.

INSTALLATION
Direct Burial

Tough UV-resistant polyethylene jacket is designed for permanent underground and exposed outdoor installations.

MOISTURE PROTECTION
Waterproof Construction

Petrol-jelly protection around the screening helps prevent oxidation and contributes to the cable's waterproof construction.

FLEXIBILITY
Flexible for Rotators

Stranded copper centre conductor and reactive braid allow tight routing and use with rotator-operated antennas.

VELOCITY FACTOR
87%

Triple-layer physically foamed polyethylene dielectric provides excellent low-loss RF performance.

Flexible Burial-Grade Coax

Built for Jobs Ordinary Flexible Coax Cannot Do

Standard flexible PVC-jacket coax is excellent inside the shack, up a mast or around a rotator, but it is not normally intended to be buried directly in the ground.

EXTRAFLEX BURY 10 is different. Its tear-resistant polyethylene outer jacket is specifically designed for outdoor and underground use, while the cable still retains the flexibility needed for tighter bends and moving antenna systems.

M&P describes it as delivering its best performance and attenuation for a 10mm stranded-core coaxial cable.

Low-Loss Performance

Premium Low-Loss Performance

At 20°C, attenuation is specified at only 1.4dB per 100m at 14MHz, 2.6dB at 50MHz, 4.6dB at 144MHz, 8.5dB at 430MHz and 15.3dB at 1296MHz.

This makes EXTRAFLEX BURY 10 particularly suitable for long permanent feed lines and VHF/UHF installations where losses in conventional coax can become a significant part of the overall system performance.

Cable Comparison

A Major Step Up from RG213 and RG-8X

Despite being approximately the same overall diameter as RG213/U, EXTRAFLEX BURY 10 provides substantially lower attenuation. The advantage over RG-8X is even greater.

Frequency EXTRAFLEX BURY 10 Belden RG213 Belden RG-8X Type
50MHz 2.6dB / 100m 4.6dB / 100m Approx. 6.9dB / 100m
100MHz 3.8dB / 100m 6.6dB / 100m Approx. 10.2dB / 100m
400MHz 8.2dB / 100m 14.1dB / 100m Approx. 21.7dB / 100m

Comparison figures use published Belden RG213 and RG-8X Type data. Performance varies between cable manufacturers and individual constructions.

Moisture Protection

Petrol-Jelly Protected and Waterproof

M&P adds a protective petrol-jelly layer within EXTRAFLEX BURY 10 to help reduce oxidation and protect the cable from moisture ingress.

Combined with the UV-resistant polyethylene outer jacket, this gives the cable the durability needed for permanent outdoor runs and direct burial.

Made for Permanent Outdoor Feed Lines

EXTRAFLEX BURY 10 is particularly useful when a feed line has to leave the shack, cross a garden or property underground and then continue up towards the antenna without changing to a different type of coax.

Flexible Construction

Flexible Enough for Rotator Antennas

The technical specification gives a 7 x 1.0mm stranded copper centre conductor with an overall diameter of approximately 2.9mm.

Combined with M&P's reactive braid, this provides much greater flexibility than would normally be expected from a rugged direct-burial cable.

Minimum bend radius is specified at 80mm for repeated bending up to 15 bends and just 40mm for a single bend or choke.

Reactive Screening

Dense 192-Wire Reactive Braid

The first screen is a 100% copper foil with an applied polyethylene layer designed to help prevent cracking during short-radius bends.

Over this is an 85% coverage reactive braid made from 192 copper-clad aluminium wires.

M&P manufactures the braid using a 24-spool process rather than a conventional 16-spool machine. The additional crossover points allow the braid to react to bending and twisting in a spring-like manner while maintaining excellent screening.

RF Isolation

Greater Than 105dB Screening

Screening efficiency is specified at greater than 105dB between 100MHz and 2000MHz.

This high level of shielding helps reduce unwanted RF ingress and radiation from the feed line, particularly useful in stations with multiple radios, amplifiers, antennas or nearby sources of interference.

High-Power Operation

High-Power Capability

M&P's 40°C power-handling data gives approximately 3013W at 14MHz, 1656W at 50MHz, 956W at 144MHz and 543W at 430MHz.

Maximum Peak Power
10,000W Maximum Peak Power

M&P specifies a maximum peak-power rating of 10kW. Actual power handling varies with operating frequency and cable temperature.

Applications

Where EXTRAFLEX BURY 10 Works Best

UNDERGROUND
Direct-Burial Feed Lines

Designed for permanent underground coax runs between the shack and antenna system.

MOVEMENT
Rotator Antennas

Unusually flexible for a burial-grade cable, making it suitable for rotator loops and moving antenna systems.

OUTDOOR
Long Outdoor Runs

Low attenuation and weather-resistant construction suit long permanent feeds exposed to the elements.

VHF / UHF
VHF and UHF

Low loss becomes particularly valuable as operating frequency and cable length increase.

POWER
High-Power Stations

Strong power handling makes it suitable for demanding HF and VHF transmit installations.

RG213
Replacing RG213

A substantial performance upgrade while remaining within the familiar 10.3mm cable size.

Selecting Cable Length

M&P Cable Length Guidance

M&P provides the following transmitting guidance for EXTRAFLEX BURY 10. These figures indicate cable lengths at which M&P rates performance as Excellent or Good and are not absolute operating limits.

Frequency Excellent Good
14MHz Up to 100m Up to 160m
28MHz Up to 75m Up to 120m
50MHz Up to 60m Up to 80m
144MHz Up to 35m Up to 60m
430MHz Up to 20m Up to 30m
1296MHz Up to 12m Up to 17m
2400MHz Up to 8m Up to 10m
Cable Design

Cable Construction

  • 7 x 1.0mm stranded copper centre conductor
  • 2.9mm overall centre conductor diameter
  • Triple-layer high-pressure physically foamed polyethylene dielectric
  • 100% copper foil first screen with applied PE layer
  • 85% coverage reactive braid
  • 192 copper-clad aluminium braid wires manufactured using 24 spools
  • Petrol-jelly protection against moisture and oxidation
  • UV-resistant polyethylene outer jacket
  • Suitable for direct burial and outdoor use
  • 10.3mm overall diameter
  • 87% velocity factor
  • Screening efficiency greater than 105dB from 100 to 2000MHz
  • Maximum peak power 10,000W
Manufacturer Documentation

EXTRAFLEX BURY 10 Datasheet

View EXTRAFLEX BURY 10 Datasheet
Product Information

EXTRAFLEX BURY 10 /.400" Technical Specifications

Specifications

General

Model EXTRAFLEX BURY 10 /.400"
Nominal Impedance 50 ohms ±3 at 200MHz
Overall Diameter 10.3mm ±0.15mm
Velocity Factor 87%
Capacitance 78pF/m ±2
Screening Efficiency Greater than 105dB, 100 to 2000MHz
Temperature Range -40°C to +60°C
Net Weight 11.6kg per 100m
Maximum Peak Power 10,000W
Spark Test 8kV
Direct Burial Yes
Waterproof Protection Petrol-jelly protected
Cable Design

Construction

Inner Conductor 7 x 1.0mm copper wires
Inner Conductor Diameter 2.9mm ±0.15mm
Dielectric Triple-layer high-pressure physically foamed polyethylene
Dielectric Diameter 7.3mm ±0.05mm
First Screen 100% copper foil with applied PE layer
Reactive Braid 85% coverage, 192 copper-clad aluminium wires, 24-spool construction
Moisture Protection Petrol-jelly protective layer
Outer Jacket UV-resistant polyethylene for direct burial and outdoor use
Inner Conductor Resistance 3.6 ohms/km
Outer Conductor Resistance 9.2 ohms/km
Flexibility

Minimum Bend Radius

Repeated Bending

80mm for up to 15 bends

Single Bend / Choke

40mm

Return Loss

Structural Return Loss

0.3 to 600MHz Greater than 30dB
600 to 1200MHz Greater than 25dB
1200 to 2000MHz Greater than 20dB
RF Loss

Attenuation at 20°C

Frequency Loss dB/100m
1.8MHz0.7dB
3.5MHz0.9dB
7MHz1.0dB
10MHz1.2dB
14MHz1.4dB
21MHz1.7dB
28MHz1.9dB
50MHz2.6dB
100MHz3.8dB
144MHz4.6dB
200MHz5.5dB
400MHz8.2dB
430MHz8.5dB
800MHz11.8dB
1000MHz13.3dB
1296MHz15.3dB
2400MHz21.7dB
3000MHz24.5dB
4000MHz29.0dB
5000MHz33.0dB
5800MHz34.9dB
6000MHz36.8dB
7000MHz40.6dB
8000MHz44.1dB
9000MHz48.1dB
10000MHz52.0dB
11000MHz55.8dB
12000MHz59.9dB
RF Power

Power Handling at 40°C

Frequency Maximum Power
1.8MHz5581W
3.5MHz4583W
7MHz3861W
10MHz3447W
14MHz3013W
21MHz2528W
28MHz2214W
50MHz1656W
100MHz1152W
144MHz956W
200MHz808W
400MHz561W
430MHz543W
800MHz392W
1000MHz348W
1296MHz302W
2400MHz215W
3000MHz190W
4000MHz161W
5000MHz142W
6000MHz127W
7000MHz116W
8000MHz106W
10000MHz91W

M&P labels its detailed power/temperature data for this cable as continuous carrier at 50% duty cycle. Observe the manufacturer's full power and temperature guidance when designing high-power systems.

Delivery Information

Shipping & Delivery

We offer a range of UK and international delivery services, including next working day delivery and selected weekend options for eligible orders. Available services, prices and estimated delivery times are shown at checkout.

All orders are despatched within 24 hours. UK domestic orders placed before 2pm are despatched the same day, provided no modification or labour service has been purchased.

Same-Day Despatch

UK domestic orders placed before 2pm are despatched the same day, excluding orders requiring modification or labour services.

Weekend Delivery

Orders requiring weekend delivery must be placed before 2pm on Friday. Orders placed on Saturday are not eligible for next-day or Sunday delivery, even if Sunday Delivery is selected at checkout.

Delivery Service Availability

Delivery options depend on the size, weight, contents and destination of your parcel. Express and weekend services are subject to availability and applicable cut-off times. Oversized or exceptionally heavy items may require a specialist delivery quotation.

Returns Information

Returns & Cancellations

To arrange a return, please contact our team at [email protected] or call 0345 2300 599.

Download Returns Form

Changed Your Mind?

Under the Consumer Contracts Regulations 2013, most purchases made online or by telephone can be cancelled within 14 days of receipt.

Cancellation Period

14 Days

Notify us of your cancellation within 14 days of receiving your goods.

Once you have notified us, you have a further 14 days to return the goods.

Condition of Returned Goods

Please handle all goods with care. Returned items must be in a resaleable condition, complete with their original packaging and all supplied accessories.

You may inspect goods as you would in a shop. However, handling beyond what is necessary for inspection may result in a lawful deduction from your refund to reflect any diminished value.

Important Conditions

Returns Exceptions

The following conditions apply to modified equipment, custom-made cable assemblies, software and labour services.

Modified Equipment & Reversal Charges

Additional return conditions may apply to equipment modified at the customer's request, including wideband transmit or receive modifications.

ML&S may charge a reasonable fee to reverse physical modifications and restore equipment to its original factory specification. Any applicable charge will be agreed in advance and deducted from your refund.

Custom-Made Cable Assemblies

Coaxial cable assemblies manufactured to a customer's specifications are excluded from the 14-day return policy and are non-refundable unless faulty.

Software & Labour Charges

Customer-requested labour and modification charges are non-refundable once the work has been completed.

Computer software may only be returned under the 14-day return policy if it remains sealed and unopened.

Postage Options

Return Postage Charges

Customers are responsible for the direct cost of returning unwanted or incorrectly ordered goods. You may arrange your own suitable return postage or choose one of our optional prepaid return services.

Standard Parcels

Royal Mail Return Label

£5.95

Per parcel

Suitable for eligible standard-sized parcels, subject to Royal Mail restrictions. Free collection is available.

Larger Parcels

DPD Return Label

£7.95

Per parcel

Suitable for larger or heavier parcels, including shipments containing batteries.

Collection Service

DPD Collection

£25.00

Per parcel

Available upon request for eligible addresses, subject to service availability.

Return Postage Information

All prepaid return charges will be confirmed before booking and deducted from your refund.

The prices above apply to eligible UK mainland returns. Oversized items, specialist products and returns from other destinations may require a separate quotation. Estimated return costs will be disclosed before purchase.

Faulty or Incorrectly Supplied Goods

Return postage charges do not apply to faulty, damaged or incorrectly supplied goods returned under statutory rights. In these circumstances, ML&S will arrange a free return using either the Royal Mail or DPD return label service described above.

DPD collection is an additional chargeable service and is not provided free of charge under your statutory rights.

Refund Information

Refunds

How Refunds Are Processed

Refunds are processed without undue delay following receipt and inspection of the returned goods, and no later than 14 days after we receive your returned parcel.

Refunds are issued to the original payment method. Any prepaid return postage charges or lawful deductions for diminished value will be itemised and provided upon request.

Product Support

Warranty Terms & Conditions

ML&S provides warranty cover on new and used equipment, subject to the conditions outlined below.

New Equipment

Minimum 2-Year Warranty

All new products supplied by ML&S include a minimum two-year warranty against manufacturing defects. Batteries are excluded and are covered by separate warranty terms.

Some manufacturers offer extended warranty cover, including a three-year warranty on eligible Yaesu equipment. Any additional cover is subject to the manufacturer's terms and conditions.

Used Equipment

3-Month Warranty

All used products supplied by ML&S include a three-month parts and labour warranty against manufacturing defects. Batteries are excluded from warranty cover.

Warranty Repairs & Exclusions

Our workshop may assess and repair faulty equipment on site or, where necessary, refer it to the manufacturer or an authorised service centre.

Warranty exclusions may include batteries, normal wear and tear, accidental damage, misuse and unauthorised modifications, as specified in the applicable warranty terms.

All warranties are provided in addition to your statutory consumer rights against ML&S, which are not limited by the warranty period.

Overseas Customers

International Returns & Warranty

Unless otherwise stated, ML&S warranty servicing is carried out in the United Kingdom. International customers must contact us before returning goods to confirm the appropriate shipping and customs requirements.

International Return Conditions

International customers are responsible for return postage unless the goods are faulty and ML&S has been notified within a reasonable time.

ML&S accepts no responsibility for additional charges arising from incorrectly completed customs documentation. Any additional duties charged to ML&S as a result will be billed to the customer before the goods are returned.

We're Here to Help

Need Help With a Return?

Our team can assist with returns, postage arrangements, equipment modifications and warranty claims.

Email ML&S

Alternatively, call us on 0345 2300 599.

Nothing in these terms excludes or limits your statutory consumer rights.