MICROHAM STATION MASTER Unique and the most advanced "combo" controller for Antenna switching, Rotator control and automatic Power Amplifier support available today. in excellent condition and supplied with accessories cables and links to download the manual and boxed.

 

USB: USB 2.0 Full speed, USB 1.1 compatible

 

Power consumption: USB – less than 100mA

Power supply – max.1.8A at +13.8V (max. +16V)

 

CAT: RxD, TxD – max. 57600 Baud, RTS fixed level output max.1mA

Levels: TTL, inverted TTL, open collector bus, RS232

 

Serial: RS232 levels, RTS fixed level output max.1mA, up to 9600 baud

 

PA CI-V: open collector bus max.40mA, up to 9600 baud

 

All relay outputs: 30VDC, 48VAC, max.2A

 

External PORT A power: max. +24V/1.3A

 

External PORT B power: max. +24V/1.3A

 

PS/2 consumption: max. 200mA at +5V

 

Rotator analog input: 10K ohm, max. +/-12V

 

Rotator pulse input: active when grounded, max.+24V/5mA

 

Rotator reference output: 9V, max.20mA

 

PA Keying output: open collector, max.+45V/800mA

 

PA Keying input: active when grounded, max.+24V/5mA

 

PA ON/OFF control: +12V, max.100mA

 

Dimensions: W 230mm (9") x H 44mm (1.73") x D 160mm (6.3")

 

Weight: 1.3 kg (1.875 lbs.)

 

 

 

 

 

  1. POWER

    LED lights when +13.8V is applied (power switch on).

     

  2. ALARM

    LED lights when “ALARM” condition happens, transmission is allowed.

    LED flashes when “ALARM” condition happens, transmission is inhibited.

     

  3. READY

    LED lights when transmission is allowed.

    LED flashes when transmit condition has been changed and will be applied on next transmission cycle.

     

  4. BUSY 

    LED lights when “BUSY” condition happens, transmission is allowed.

    LED flashes when “BUSY” condition happens, transmission is inhibited.

     

  5. FUNC/MENU

    Short press and release opens “Function” list.

    Press and hold for more than one second opens “Menu” list.

     

  6. ENCODER

    Rotary encoder with push button. Function vary on configuration and antenna selection.

     

  7. <-/YES

    Button for browsing between available antennas backward and menu navigation.

     

  8. ->/NO

    Button for browsing between available antennas forward and menus navigation.

 

 

 

 

  1. DC 13.8V

    Power Supply - 2.1 x 5.5 mm coaxial jack, center is positive (+).

     

  2. iLINK

    MiniDIN-6 for connection with microHAM “keyer” or function expansion module.

     

  3. USB 

    USB B connector for computer connection.

    Standard USB A-B cable. 

     

  4. SERIAL

    RS232 level serial port.

    DB9 female jack.

    See Appendix “Connectors” for details.

     

  5. PA

    DB15 female jack for connection with Power Amplifier.

    Compatible with microHAM “CAT” cables

    See Appendix “Connectors” for details.

     

  6. PORT A

    DB25 female jack for antenna switch connection.

    See Appendix “Connectors” for details.

     

  7. PS/2

    MiniDIN6 for PS/2 keyboard or PS/2 keypad.

     

  8. INHIBIT

    Power inhibit output for Yaesu's transceivers.

    RCA jack  TIP - Signal  SHELL - GND 

     

  9. CAT

    4 pole 3.5mm phono jack for transceiver control. Compatible with microHAM “CAT” cables.

  10. GND 

    Terminal for connection to station ground.

     

  11. iLINK

    MiniDIN-6 for connection with microHAM “keyer” or function expansion module.

     

  12. POWER

    Power Switch.

     

  13. ROTOR

    DB15 female jack for connection with Antenna Rotator.

    See Appendix “Connectors” for details.

     

  14. PORT B

    DB25 female jack for antenna switch, BPF and/or sequencer connection.

    See Appendix “Connectors” for details.

     

  15. PTTIN

    PTT Input for connection with PTT output from transceiver or PAPTT output from microHAM “keyer”. Active when closed to ground.

    RCA jack TIP - Signal   SHELL – GND

     

 

 

Shipping:

We have several shipping options for our products, including next-day and Saturday/Sunday delivery for certain items. Please see these options at checkout.

Returns:

If you have any equipment that needs to be returned to Martin Lynch & Sons, please fill out the form below:

Click here for returns form

Upon receipt of goods you have 14 days to return goods however the goods must be returned in original packaging and care must have been taken with the goods you wish to return. Under distance selling regulations you are not entitled to any refund on carriage charges or modification charges made at your request.

Warranty Terms and Conditions

Outside of the 14 faulty return period, returned items cannot be accepted, unless covered by manufacturer's warranty. We will repair as much as possible on site however in exceptional circumstances products may have to be returned to the manufacturer of distributor.

For repairs/replacements under manufacturer’s warranty for any item please download a ML&S return form from the link above and return to ML&S with the faulty product.

International Warranty information

Warranty service for items we sell is available in the U.K. only, unless otherwise noted. It is your responsibility to pay freight for returned items to the U.K. and back to you for desired warranty coverage. All of our NEW products come with a minimum 12 month warranty, (Yaesu & Icom 24 months), with up to 90 days on second-hand equipment. Items returned for service must state "returned goods for repair" on the return air waybill or U.K. import customs duties apply and will be added to your invoice. For more info about returning items please contact our customer help desk, [email protected]